Lasensor Product | LPC-S5100 Airborne Particle Counter | 100 L/min Cleanroom Monitoring

Portable Airborne Particle Counter

The LPC-S5100 Airborne Particle Counter is a 100 L/min high-flow particle counter designed for cleanroom and GMP environmental monitoring. With a 316L stainless steel housing, 8-inch touchscreen, automatic sampling-point calculation, large data storage capacity, and comprehensive data integrity functions, it provides an efficient solution for routine airborne particle monitoring in controlled environments.
The instrument supports multiple particle size channels from 0.5 to 25 µm and provides time- or volume-based sampling. Its multi-level user management, audit trail, protected data records, and PDF/CSV export functions support data management requirements associated with FDA 21 CFR Part 11.
Description
product-1-1

18 YEARS EXPERIENCE

There are more than 30 products to choose from to meet your every need.

Contact now

Products Description

image.png

1. Product Overview

  • 100 L/min high flow rate for efficient air sampling and cleanroom monitoring.

  • Measures particles in six size channels: 0.5, 1.0, 3.0, 5.0, 10.0, and 25.0 µm.

  • Designed for cleanroom environments and GMP-related monitoring applications.

  • Supports both time-based and volume-based sampling.

  • Sampling time can be configured from 1 to 999,999 seconds.

  • Built-in functions allow users to name rooms and sampling locations.

  • Automatically calculates the required number of sampling locations based on the specified area.

2. Product Features

  • 316L stainless steel housing, resistant to commonly used cleanroom disinfectants.

  • 8-inch color touchscreen for intuitive operation and real-time measurement display.

  • Semiconductor laser source with a service life of more than 35,000 hours.

  • Particle concentration trends can be displayed using line and bar graphs.

  • Built-in thermal printer for direct printing of measurement results.

  • Rechargeable lithium-ion battery supports up to 8 hours of continuous operation.

  • Compact design with a weight of approximately 6.5 kg, allowing the instrument to be moved between sampling locations.

3. Data Integrity & Management

The LPC-S5100 is designed with data management functions for regulated cleanroom environments.

  • More than three levels of user permissions with different system access rights.

  • Account and password management for controlled system access.

  • Audit trail records operations performed by logged-in users.

  • Measurement records are protected against editing or alteration.

  • Stores up to 1 million measurement records.

  • Measurement data can be exported through USB in PDF or CSV format.

  • Supports Ethernet communication via Modbus TCP for integration with external systems.

  • Data management functions are designed to support FDA 21 CFR Part 11 requirements.

4. Cleanroom-Compatible Design

The LPC-S5100 is designed for repeated use in controlled environments.

  • 316L stainless steel casing provides resistance to commonly used disinfectants.

  • The exhaust design minimizes disruption to the surrounding laminar airflow.

  • The exhaust outlet incorporates a built-in filter with an efficiency of >99.97% at 0.2 µm.

  • The instrument can operate under environmental conditions of 5–35°C and 0–98% RH, non-condensing.

5. Sampling & Measurement

The LPC-S5100 provides flexible sampling functions for different monitoring procedures.

  • 100 L/min flow rate for high-volume air sampling.

  • Time or volume sampling modes can be selected according to the monitoring procedure.

  • Adjustable sampling time and sampling interval.

  • Zero count: ≤10 min.

  • Maximum concentration: 1,000,000 pcs/ft³ (35,000 pcs/L).

  • Particle size resolution: <15% at 0.5 µm, according to ISO 21501-4.

6. Battery & Power Supply

  • Built-in rechargeable lithium-ion battery.

  • Up to 8 hours of continuous operation on battery power.

  • Universal power supply: 110–240 V, 50–60 Hz.

  • Power consumption: ≤50 W.

7. Applications

The LPC-S5100 can be used for airborne particle monitoring in controlled environments, including:

  • Pharmaceutical manufacturing

  • GMP cleanrooms

  • Biotechnology facilities

  • Semiconductor and electronics cleanrooms

  • Other controlled production and testing environments

It can be used for routine environmental monitoring, cleanroom classification-related measurements, and other particle monitoring procedures requiring high-volume sampling and traceable data management.

8. Technical Specifications

ItemSpecification
ModelLPC-S5100
Flow Rate100 L/min
Particle Size Channels0.5, 1.0, 3.0, 5.0, 10.0, 25.0 µm
Size Resolution<15% @ 0.5 µm, ISO 21501-4
Maximum Concentration1,000,000 pcs/ft³ (35,000 pcs/L)
Zero Count≤10 min
Sampling ModeTime / Volume
Sampling Time1–999,999 s
Light SourceSemiconductor laser, >35,000 h
CommunicationEthernet, Modbus TCP
Data Storage1 million records
Data ExportUSB, PDF / CSV
Display8-inch color touchscreen
PrinterBuilt-in thermal printer
BatteryRechargeable lithium-ion battery, up to 8 h
Power Supply110–240 V, 50–60 Hz
Power Consumption≤50 W
Housing316L stainless steel
Weight6.5 kg
Dimensions230 × 225 × 200 mm
Working Temperature5–35°C
Working Humidity0–98% RH, non-condensing
Atmospheric Pressure86–106 kPa
StandardsGMP-2010, ISO 14644-1:1999, ISO 14644-1:2015