18 YEARS EXPERIENCE
There are more than 30 products to choose from to meet your every need.
Products Description

1. Product Overview
The LPC-110A uses the optical light-scattering principle to detect and count airborne particles according to their size.
Designed for inline and continuous particle monitoring.
Detects particles from 0.1 µm.
28.3 L/min flow rate provides efficient air sampling.
Compact structure makes it suitable for installation in limited spaces.
Measurement data can be transmitted to an external monitoring system.
Suitable for integration into centralized cleanroom monitoring platforms.
2. Product Features
Long-life semiconductor laser with a lifespan of more than 35,000 hours.
Stable optical performance for reliable particle counting.
Compact and lightweight design, weighing approximately 2.8 kg.
RS485 communication for connection with external monitoring systems.
Supports Modbus RTU and customized communication protocols.
External vacuum pump configuration allows flexible system installation.
No built-in display, making the instrument suitable for applications where measurement and control are handled by a central system.
3. Designed for Inline Monitoring
Unlike portable particle counters that are moved from one sampling point to another, the LPC-110A is designed to remain installed at a designated monitoring location.
Enables continuous monitoring without repeated manual sampling.
Can be installed at fixed monitoring points within a cleanroom or production environment.
Particle data can be transmitted to a central monitoring system in real time.
Multiple LPC-110A units can be integrated into one monitoring network.
Suitable for applications where continuous particle information is required for process or environmental monitoring.
This design can help reduce repeated manual measurements and provide a more consistent monitoring workflow.

4. Particle Detection
The LPC-110A uses a semiconductor laser as its optical light source and measures airborne particles according to different particle size channels.
Particle size channels: 0.1, 0.2, 0.3, 0.5, 1.0, 2.0, 3.0, and 5.0 µm.
Size resolution: <15% at 0.5 µm, complying with ISO 21501-4.
Counting efficiency at 0.5 µm: 50% ±20%.
Maximum concentration: 1,000,000 pcs/ft³.
Zero count: ≤10 min.
The multi-channel configuration allows particle concentration changes to be monitored across different size ranges rather than relying on a single particle-size threshold.
5. Communication & System Integration
The LPC-110A is designed to function as a measurement unit within a larger particle monitoring system.
RS485 interface for data communication.
Supports Modbus RTU protocol.
Customized communication protocols can be provided according to integration requirements.
Can communicate with external software, controllers, or monitoring platforms.
Suitable for centralized collection of data from multiple monitoring points.
With centralized communication, particle counters installed at different locations can be connected to a common monitoring architecture.
6. Compact Installation
The LPC-110A is designed with installation flexibility in mind.
Dimensions of approximately 205 × 121.5 × 160 mm.
Weight of approximately 2.8 kg.
Compact size for installation where available space is limited.
304 stainless steel housing as standard.
Customized stainless steel options, including 316L, are available.
External vacuum pump configuration provides flexibility for different installation layouts.
7. Applications
The LPC-110A can be used in applications requiring continuous or integrated airborne particle monitoring, including:
Cleanroom monitoring
Pharmaceutical and controlled environments
Semiconductor and electronics manufacturing
Process equipment monitoring
Filter material testing
Mask testing
Centralized environmental monitoring systems
Automated particle monitoring systems
For applications with multiple monitoring points, the LPC-110A can be integrated into a centralized system to collect particle data from different locations.
8. Technical Specifications
| Item | Specification |
|---|---|
| Model | LPC-110A |
| Type | Inline Airborne Particle Counter |
| Flow Rate | 28.3 L/min |
| Particle Size Channels | 0.1, 0.2, 0.3, 0.5, 1.0, 2.0, 3.0, 5.0 µm |
| Size Resolution | <15% @ 0.5 µm, ISO 21501-4 |
| Counting Efficiency | 50% ±20% @ 0.5 µm |
| Maximum Concentration | 1,000,000 pcs/ft³ |
| Zero Count | ≤10 min |
| Light Source | Long-life semiconductor laser, >35,000 h |
| Communication | RS485 |
| Protocol | Modbus RTU / Customized protocols |
| Vacuum Pump | External |
| Display | Without built-in display |
| Power Supply | DC 24 V |
| Housing | 304 Stainless Steel; customized 316L available |
| Weight | 2.8 kg |
| Dimensions | 205 × 121.5 × 160 mm |
| Operating Temperature | 5–35°C |
| Operating Humidity | 0–98% RH, non-condensing |
| Storage Temperature | -15–60°C |
| Storage Humidity | 0–98% RH, non-condensing |
9. Why Choose LPC-110A?
0.1 µm particle detection for fine particle monitoring.
28.3 L/min flow rate for efficient sampling.
Inline design for continuous monitoring.
RS485 / Modbus RTU for easy system integration.
Compact 2.8 kg design for flexible installation.
Long-life semiconductor laser for stable operation.
Supports customized communication for different monitoring architectures.
The LPC-110A provides a compact and flexible solution for applications that require continuous airborne particle measurement and integration with a centralized monitoring system.